A modern heat pump HERO PREMIUM guarantees efficient home heating and cooling, and hot water. A black matt ABS housing ensures aesthetic and modern appearance. This pump makes use of a complete inverter solution with an ecological R32 working medium, as well as technological EVI.
HERO PREMIUM air-water heat pumps dedicated to the European market were developed with the use of the state-of-the-art technology of heat pumps and modern design in order to satisfy the strict requirements of efficiency, stability and silent work. HERO PREMIUM series not only makes use of Green Gas R32 technology and EVI inverter technology, but it also has A+++ energy label; therefore, this device is not only energy efficient but it also qualifies for the highest funding level.
A modern design with a corrugated surface and without any screws guarantees the smart appearance of the heat pump. ABS is resistant to corrosion what extends the lifespan of the device.
Owing to the unique, sound absorbent internal structure, the pump acoustic pressure is maintained at the level of 42 dB (A) within the distance of 1 m.
Comparing with the commonly used cooling media, such as R-22 and R-410A, R32 has two thirds lower potential for creating the greenhouse effect and it is characteristic for an insignificant environmental impact.
Owing to Inverter EVI unique technology, HERO PREMIUM may function efficiently at the temperature of -25°C, maintain a high COP coefficient and reliable stability.
HERO heat pumps are a perfect way to reduce heating costs and guarantee the actual contribution to the environment protection. The diagram below presents the possibilities of a single-family house owner deciding on HERO PLUS or HERO PREMIUM heat pump. These devices are perfect for floor heating systems, heaters, fan coil units or the combination of all these solutions.An additional advantage of HERO PUMPS is also the possibility of using HYDROBOX which is a ready solution in a stylish housing for the external installation in a building. Our offer includes two variants with hot water or without hot water.
It is worth remembering that Hero heat pumps enable managing 5 independent hydraulic systems. By means of the controller and room thermostats they are adjusted automatically depending on the external and internal temperature in rooms.
Controler ecoMULTI it enables controlling the traditional systems based on a buffer, coupling, glycol-water exchanger or direct system. A dedicated application ensures the convenient operation not only of the heat pump but of the whole installation.
Contact the our partner who will help you choose the right KIPI devices and enjoy an efficient, maintenance-free and economical source of heat.
Contact us to place an order for our device and enrich your offer with an efficient, maintenance-free and economical source of heat.
POWER AND EFFICIENCY | HERO PREMIUM Q8 | HERO PREMIUM Q12 | HERO PREMIUM Q21 |
Heating power at A7/W35 [kW] | 2,42|8,72 (min. | maks.) | 4,77|12.69 (min. | maks.) | 7,40|21,67 (min. | maks.) |
Heating power at A2/W35 [kW] | 1,74|7,48 (min. | maks.) | 3,48|10,93 (min. | maks.) | 6,85|19,13 (min. | maks.) |
Heating power at A-7/W35 [kW] | 1,32|6,02 (min. | maks.) | 3.17|8,80 (min. | maks.) | 5,51|14,85(min. | maks.) |
Heating power at A-7/W55 [kW] | 1,07|4,82 (min. | maks.) | 2,52|7,88 (min. | maks.) | 4,40|12,13 (min. | maks.) |
Maximum power supply temperature [°C] | 60 | 60 | 60 |
Cooling power at A35/W7 [kW] | 1,56|6,0 | 2,20|10,0 | 6,3|18,4 |
COP at A2/W35 | 4,45 (partial loading) | 4,34 (partial loading) | 4,53 (partial loading) |
COP at A7/W35 | 4,85 (partial loading) | 4,91 (partial loading) | 5,10 (partial loading) |
Voltage and current [V;A] | 230|13 | 3×400|7,6 | 3×400|7,6 |
Maximum electricity consumption [kW] | 2,9 | 4,4 | 6,16 |
Application limits [°C] | od- 25 do 43 | od -25 do 43 | od -25 do 43 |
ACOUSTICS | |||
External acoustic power 1m [dB(A)] | 42 | 45 | 46 |
Minimum external acoustic power 1m [dB(A)] | 57 | 60 | 61 |
GENERAL DATA | |||
Hot water storage tank [l] | – | – | – |
Cooling | Tak | Tak | Tak |
Integrated electric heating element [kW] | 6 | 6 | 6 |
Hermetically closed | Tak | Tak | Tak |
Working medium | R32 | R32 | R32 |
Medium quantity [kg] | 1,3 | 1,8 | 2,3 |
CO2 equivalent [t CO2] | 0,88 | 1,22 | 1,55 |
Heat pump dimensions Width x Depth x Height [mm] | 1167 x 407 x 795 | 1287 x 458 x 928 | 1250 x 540 x 1330 |
Packed heat pump weight | net [kg] | 102|90 | 123|100 | 175|155 |
ENERGY EFFECTIVENESS CLASS | |||
A device with a regulator – power supply temp. 35°C | A+++ | A+++ | A+++ |
A device with a regulator – power supply temp. 55°C | A++ | A++ | A++ |
Ta strona korzysta z plików cookies w celu świadczenia usług na najwyższym poziomie. Dalsze korzystanie ze strony oznacza, że zgadzasz się na ich użycie.
1) The administrator of your personal data is BTI Gumkowski Sp. z o. o. Sp. k. hereinafter referred to as the Administrator. The administrator conducts the processing of your personal data,
2) Your personal data will be processed for information and marketing purposes and will not be made available to other recipients, the basis for the processing of your personal data is art. 6 of Regulation (EU) 2016/679 of the European Parliament and of the Council of 27 April 2016 on the protection of individuals with regard to the processing of personal data and on the free movement of such data, and repealing Directive 95/46 / EC (general regulation on data protection ),
3) Providing data is necessary to perform the legal obligations incumbent on the administrator, in the event of failure to provide data, it is impossible to effectively perform them,
4) You have the right to:
• requests from the Administrator to access their personal data, rectify them, delete or limit the processing of personal data,
• object to such processing,
• data portability,
• lodging a complaint to the supervisory body,
• withdrawal of consent to the processing of personal data.
5) your personal data is not subject to automated decision making, including profiling,
I declare that I have read the above content, understand and accept its terms.